AST Panel Kit

NEED

The discovery and use of antibiotics are two of the mostsignificant breakthroughs in twentieth-centurymedicine—leading to dramatic reductions in humanmorbidity and mortality. One emerging problem withantibiotics is the development of antibiotic-resistant bacteria.Antimicrobial resistance (AMR) occurs when microbes evolvemechanisms that protect them from the effects ofantimicrobials. Infections due to AMR cause millions ofdeaths each year. So, antibiotic resistance is one of the mosturgent threats to public health. Effective treatment ofinfection depends on the accurate identification of thepathogen(s) and the correct choice of antibiotic(s). Henceaccurate antimicrobial susceptibility (AST) profiling of a pathogen is very important.

Test Overview

TRUPCR® AST Panel Kit is an in vitro nucleic acid amplification assay for the qualitative detection & differentiation of antimicrobial resistance genes encoding resistance to antibiotics - Trimethoprim/Sulfamethoxazole (SXT), Extended-spectrum beta-lactams (ESBLs), Carbapenems, Vancomycin and Methicillin using Real Time PCR System. It includes five tubes targeting fourteen antibiotic resistant genes. This assay is based on TaqMan hydrolysis probe which allows higher specificity and sensitivity. 

The targets are detected with the help of four different dyes (FAM/Green, HEX/Yellow, Texas Red/Orange and Cy5/Red). This kit can be used with the extracted genomic DNA from clinical samples or cultured isolates.

 

AST Panel Kit
Tube* Antibiotic Target Gene Dye
1   Sul2 FAM
SXT dfrA1 Texas Red
  dfrA5 Cy5
2   blaCTX-M FAM
ESBLs blaTEM Texas Red
  blaSHV Cy5
3   blaKPC FAM
Carbapenems set 1 blaNDM Texas Red
  blaVIM Cy5
4   blaOXA-48 FAM
Carbapenems set 2 blaIMP Texas Red
5 Methicillin mecA FAM
Vancomycin vanA Texas Red
  vanB Cy5

 

Technical Specifications

  • Sample Type – Blood Culture, Rectal swab, mid-stream clean catch urine or cultured isolates 
  • AST profiling targeting 14 genes with 5 different classes of antibiotics
  • Clinical Validation – Validated on more than 500 clinical samples
  • Target Regions – Pathogen specific conserved regions 
  • LoD Data = 103 Copies/reaction
  • Room temperature reaction setup
  • UNG is included in the master mix to avoid carry over contamination
  • Reaction Volume - 20µl in each tube
  • Compatible Instruments – Applied Biosystems™ 7500 series, Applied Biosystems™ QuantStudio® series, Bio-Rad CFX96, MIC PCR

Ordering Information:

CAT. NO. PRODUCT CONTENTS
3B361 TRUPCR® AST Panel Kit 48 Rxns
3B362 TRUPCR® AST Panel Kit 96 Rxns

 

To arrange a visit or to enquire about any of our products, please feel free to contact us and one of our representatives will be in touch within 24 hours